PRODUCT

Setaflash Series 3e ActiveCool Flash Point Tester – Corrosion Resistant Cup – 33270-0

Setaflash Series 3e ActiveCool provides fast and reliable flash point results and requires minimum operator expertise. It has been designed to rapidly and efficiently carry out Flash / No Flash tests to determine the flash point of liquids and semi-solids in the 10 to 135 °C temperature range.

• Compliance
• Safety
• Product quality
• 2 ml of sample and a result in less than 2 minutes

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Setaflash Series 3 ActiveCool has a very simple user interface with colour digital display and touch screen icons which guide the operator through a straightforward testing process. For easy record keeping the instrument stores test results which can be saved and transferred via a USB port.

The versatile range of Setaflash instruments is ideal for use in the laboratory, production line or for portable test applications.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Setaflash Series 3e ActiveCool Flash Point Tester – Corrosion Resistant Cup – 33270-0

Features

  • Flash / No Flash & Ramp modes
  • Electric ignitor
  • 10 to 135°C temperature range
  • Flash point test in less than 2 minutes
  • Small sample size (2 or 4ml)
  • Automatic flash detection
  • Electronic peltier cooling
  • Inbuilt touch screen
  • Inbuilt USB port
  • Portable operation
  • °C or °F display

specifications

TEMPERATURE RANGE 10 to 135 °C
SAMPLE CUP MATERIAL Stainless steel
TEST MODE Rapid Equilibrium and Ramp
SAMPLE SIZE 2 ml for flash points up to 100 °C 4 ml for flash points above 100 °C
TEST DURATION 1 minute below 100 °C, 2 minutes above 100 °C, or user determined 1 to 99 minutes
RAMP RATE 2 °C/min ramp
HEATING AND COOLING SYSTEM Peltier cell
POWER 200 W (maximum)
VOLTAGE 100/240 V. 50/60 Hz
IGNITOR Electric
SIZE (HXWXD) 195 x 295 x 140 mm
WEIGHT 3 kg

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

Setaflash Series 3e ActiveCool Flash Point Tester – Corrosion Resistant Cup – 33270-0

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for 33270-0

High Temperature Ignitor for Series 8 and Series 3 – 82000-202

High Temperature Ignitor for use use with the Series 8 and Series 3 ActiveCool Flash Point Testers.

Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311

4 ml sample volume syringe, which must be used for flash points above 100 °C.

Flash Detector Assembly – 13740-425

For use with the Setaflash Series 3 Flash Point Tester range.

Sample Well O-ring, Viton (pack of 5) – 82150-001

Pack of 5 x 1/16th inch Viton O-rings, for use with the Setaflash Series 8 Flash Point Tester (82100-0 & 82150-0).

Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009

2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.