PRODUCT

  1. Home
  2. chevron_right
  3. Products
  4. chevron_right
  5. Laboratory Supplies
  6. chevron_right
  7. Titration
  8. chevron_right
  9. Automatic Titrator
  10. chevron_right
  11. AT 710
  12. chevron_right
  13. Automatic Potentiometric Titrator [AT-710B]

Automatic Potentiometric Titrator [AT-710B]

High-performance titrator at a lower price

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Information stored in the electrode cable , pH glass electrode only(Smart electrode)
  • New burette unit
  • Measurement results are converted to PDF and can be stored in a USB flash drive
  • By connecting an Android device , a titration curve can be displayed in real-time

specifications

Type Automatic Potentiometric Titrator
Model AT-710B
Product configuration AT-710 + IDP-100 + Propeller stirrer
Detection range 1) Potentiometric : -2000mV to +2000mV

2)pH :-20.000 to 20.000pH

3)Temp. : 0 to 100°C

Titration mode Auto Titration , Auto Intermit , Intermit , Stat
Method 20 (Max 2 methods can be linked)
Kinds of titration Potentiometric (acid/base , redox , precipitation) , Photometric , Polarization , Conductivity
Titration form Full titration (Auto EP detection) , EP Stop , Level Stop
Special application Measurement of electrode potential (pH , potential) , Acid dissociation constant (pKa)
Key operation Sheet key
Displays 1) White LED-backlit LCD

2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish / German / French

3) 1-channel display

Calculation Concentration of content , statistics data processing (mean , SD and RSD) and automatic averaging of blank and factor value
Data storage 50 samples
GLP conformance Registration of operator / Record of check results / Record of electrode calibration / Verification of burette capacity / Management of conduction tim
Burette size 20mL glass burette with brown cover (Standard)
Optional burette units : 10mL , 5mL , or 1mL
Burette accuracy 50mL burette(Auto dispenser) +/- 0.5mL
20mL burette +/- 0.02mL ; reproducibility +/- 0.01mL
10mL burette +/- 0.015mL ; reproducibility +/- 0.005mL
5mL burette +/- 0.01mL ; reproducibility +/- 0.003mL
1mL burette +/- 0.005mL ; reproducibility +/- 0.001mL
Preamplifier 1) STD:pH (mV) and mV , 2 inputs (Standard)

2) PTA:pH (mV) , mV and photometric , 3 inputs

3) POT:pH (mV) , mV and polar , 3 inputs

4) CMT:pH (mV) , mV and conductivity ,3 inputs (factory setting required)

5) TET:pH (mV) 2 ways and mV , inputs (factory setting required)

External I/O RS-232C port x2 : for Dot matrix printer/Electronic balance/Data Capture Software (SOFT-CAP)

SS-BUS x1 : for Multiple sample changer , APB

ELE. x1 : for Smart electrode

USB x1 : for USB flash drive , Thermal printer , A4 printer , Keyboard , Barcode reader , Foot switch , USB HUB

TEMP.COMP. x1 : Input terminal for temperature sensor to correct reagent volume , sensor Pt100 , temperature reading accuracy : +/- 0.5°C (burette 1 only)

Extensibility Automatic piston burette :
Can control max 10 burette drives (Including two built-in burette drives)
Multiple sample changer : CHA-700
Ambient condition 1) Temperature:5 to 35°C

2) Humidity:85%RH or below (no condensation)

Power source AC100 to 240V +/- 10% 50/60 Hz
Power consumption Main unit : Approx. 20W

Printer : Approx. 7W

Dimensions Titration unit : 141(W) x 296(D) x 367(H)mm (not incl. tubing)

Printer : 106(W) x 180(D) x 88(H) mm

Weight Titration unit : Approx. 4.0kg

Printer: Approx. 0.4kg

Conformity standard CE marking EMC : EN61326-1 LVD : EN61010-1 RE Directive
Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

Automatic Potentiometric Titrator [AT-710B]

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for AT-710B

Software for Automatric Potentiometric Titrators [AT-Win]

AT-Win software enables your PC to control KEM’s Automatic Potentiometric Titrators
e.g., AT-710B, AT-700, AT-510 or AT-500N.

Analysis Software for Titration Results [Tview6]

This software allows to capture the data stored in the titrators (AT-710B,AT-700,MKA-610, MKC-610, AT-610 and AT-510) on a personal computer through CF memory card to manage/analyze titration results.

Data Acquisition Software [SOFT-CAP]

This software allows to capture the data stored in the titrators (AT-710B,AT-700,MKA-610, MKC-610, AT-610 and AT-510) on a personal computer through CF memory card to manage/analyze titration results.

Multiple Sample Changer [CHA-700]

6 or 11 samples can be loaded for continuous measurement with connection of AT-710M

, AT-710S , AT-710B and AT-700 Automatic Potentiometric titrator.

Multiple Sample Changer [CHA-600]

Allow to measure 12 or 18 samples in succession.
Sample changer exclusive for AT-710M , AT-710S , AT-610 and AT-510 titrators.

Piston burette [APB-610]

Allow to measure 12 or 18 samples in succession.
Sample changer exclusive for AT-710M , AT-710S , AT-610 and AT-510 titrators.

Electrodes

For aqueous, non aqueous, acid-base, redox, polarization titration and chelate titration.

Propeller Stirrer

This option is attached to either a magnetic stiller stand or titration
stand for use.

Menu