PRODUCT

In-line Conductivity Sensor – 99500-0

The In-line Conductivity Sensor is an inline system that provides real time measurement of conductivity in pipelines using high accuracy AC measurement technology.

The system can be connected to a refinery/terminal management system to provide an automatic and continuous record of product conductivity levels, eliminating the requirement for manual sampling and record keeping. When installed with an automatic dosing system the in-line sensor allows automated additive dosing to maintain the conductivity within specified limits.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • In-line conductivity and temperature measurement conforming to ASTM D2624
  • Conductivity range 0 to 2000 pS/m
  • Accuracy +/-2% of reading
  • Temperature range -40° to 85 °C +/-0.5°C
  • Standard 16 bar max line pressure (high pressure model available)
  • 4-20 mA output
  • Stainless Steel construction
  • ATEX, FM, IEC Certified (note – model dependent)

Specifications

Range 0 to 2000 pS/m
Accuracy +/-2 pS/m (+/-2% of reading)
Pressure 16 bar max pressure
Temperature Range -40° to 85 °C, Accuracy +/-0.5 °C
Resolution 0.1 pS/m
Sensor Type 316 SS Coaxial Electrode
Calibration Internal Source Zero and Scale
Certification Ex II 2 G Ex db ia IIB+H2 T4 Gb
CCCN Code Tariff 90318080

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

JF-1A In-Line Conductivity Sensor Brochure

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for In-line Conductivity Sensor – 99500-0

1″ANSI B16.5 300 Adaptor – 99517-0

1″/25 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

2″DN50 PN25 Flange Adaptor – 99515-0

2″/50 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

3″DN80 PN20 Flange Adaptor – 99516-0

3″/80 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

4″ANSI B16.5 150 Flange Adaptor – 99514-0

4″/100 mm adaptor and fitting for use with the In-line Conductivity Sensor (JF-1A), reference 99500-0.

3″ANSI B16.5 150 Flange Adaptor – 99513-0

3″/80 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

2″ANSI B16.5 300 Flange Adaptor – 99512-0

2″/50 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

2″ANSI B16.5 Flange Adaptor – 99511-0

2″/50 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

1″NPT Adaptor for Ball Valve – 99510-0

1″/25 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).

JF-1A Local Readout Display M20 Enrty(ATEX) – 99508-0

A loop powered field indicator in a single compartment housing for use with the JF-1A Inline Conductivity Sensor (99500-0).

Explosion proof enclosure 5-digit LC display, Aluminium die cast housing, M20 cable entry and ATEX II2(1)G EX ib[ia] IIC T6/T5/T4.

Supplied with works calibration certificate.

JF-1A USB Serial Test Cable – 99509-0

JF-1A Local Readout Display(FM) – 99507-0

A loop powered field indicator in a single compartment housing for use with the JF-1A Inline Conductivity Sensor (99500-0).

Explosion Proof Enclosure 5-digit LC display, Aluminium die cast housing, NPT1/2 Cable entry and FM approval.

Supplied with works calibration certificate.

1.5″ANSI B16.5 150 Flange Adaptor – 99518-0

1.5″/40 mm adaptor and fitting for use with the In-line Conductivity Sensor (99500-0).