- Silica-based packed columns for aqueous SEC analysis.
- Suitable for the analysis of proteins and enzymes.
- Fulfills USP-NF L20, L33 and L59 requirements.
|
| KW400 |
- Reduced packing material particle size enhances performance.
- Three to four-fold higher sensitivity than KW-800 series
- KW405-4F is applicable analyzing samples with molecular weight above 1000000
- Fulfills USP-NF L20, L33 and L59 requirements.
|
| LW-803 |
- Pore size specifically controlled for analyzing proteins with a molecular weight of several hundred of thousand.
- High performance analysis of antibody drugs and various proteins.
- High lot-to-lot reproducibility.
- Fulfills USP-NF L20, L33 and L59 requirements.
|
| LW-403 4D |
- Rapid analysis column of LW-803.
- Achieves approximately halved analysis time compared with standard column.
- Fulfills USP-NF L20, L33 and L59 requirements.
|
| SB-800 HQ |
- Polymer-based packed columns for aqueous SEC (GFC) analysis.
- Supports a wide range of molecular weight sample analysis.
- The eluent can be replaced with DMF (except SB-802 HQ for gelatin’s mean molecular weight determination is comparable with PAGI method (Ver. 10, Japan)
- Fulfills USP-NF, L38 and L39 requirements.
- SB-802 HQ fulfills USP-NF L25 requirements.
- SB-802.5 HQ fulfills USP-NF L25 requirements.
- SB-803 HQ fulfills USP-NF L37 requirements.
|
| SB-807 HQ |
- Column bleeding allows its use with light scattering detectors.
- The eluent can be replaced with DMF enabling the analysis of polar polymers.
- Fulfills USP-NF, L38 and L39 requirements.
|
| LB-800 |
- Polymer-based packed columns for aqueous SEC (GFC) analysis.
- Low column bleeding allows its use with light scattering detectors.
- The eluent can be replaced with DMF enabling the analysis of polar polymers.
- Fulfills USP-NF, L38 and L39 requirements.
- LB-802.5 fulfills USP-NF L25 and L89 requirements.
- LB-803 fulfills USP-NF L37 requirements.
|
| KF-800 |
- Standard organic solvent SEC (GPC) column.
- Supports a wide range of application from low to high molecular weight compounds.
- Fulfills USP-NF L21 requirements.
|
| KD-800 |
- Standard organic solvent SEC (GPC) column.
- Supports a wide range of application from low to high molecular weight compounds.
- Fulfills USP-NF L21 requirements.
|
| KF-400HQ |
- About 1.5 times better separation performance than standard columns, obtain higher resolution.
- About 4 times better sensitivity than that of standard columns, supports high sensitivity analysis. The amount of solvent used is reduced to about a third.
- Improved applicability of solvent replacement.
- Fulfills USP-NF L21 requirements.
|
| HK-400 |
- Newly developed styrene divinylbenzene copolymer monodisperse particles.
- Analysis time is reduced to about a sixth of conventional column’s analysis time.
- Low column pressure even under high flow rate does not require a UHPLC system.
- The amount of solvent used is reduced to about a sixth.
- Fulfills USP-NF L21 requirements.
|
| LF |
- Packed with unique multi-pore gels with a wide pore-size distribution.
- Highly linear calibration curve without inflection points.
- Achieves highly precise molecular weight distribution determination.
- Enables analysis over a wide molecular weight range.
- Rapid analysis column (LF-604) and high-performance analysis column (LF-404) are also available.
- LF-604 and LF-404 reduce solvent use.
- Fulfills USP-NF L21 requirements.
|
| FP-2002 |
- Newly developed styrene divinylbenzene copolymer monodisperse particles.
- Can deliver t four times higher flow rate (10 ml/min or more) compared with conventional products.
- Achieves rapid recycling separation.
- Suitable for the separation of samples in a wide molecular weight range due to its wide linear range pore volume.
- Usable with various organic solvents such as THF, toluene, dichloroethane, ethyl acetate, DMF, and acetone used in GPC analysis in addition to chloroform.
|
| SH1011, SH1821 |
- Columns for simultaneous analysis of saccharides and organic acids (counter ion: H+)
- Separates neutral sugars by size exclusion mode and organic acids by ion exclusion mode
- Suitable for the analysis of uronic and aldonic acids
- Fulfill USP-NF L17 and L22 requirements
|
| SC1011
SP0810
KS-801
KS-802
|
- Separates saccharides by combination of ligand exchange and size exclusion modes
- Three types of counter ions are available: Ca2+, Pb2+ and Na+
- Only water is required for the analysis of neutral sugars
- SC1011 fulfills USP-NF L19 and L22 requirements
- SP0810 fulfills USP-NF L22 and L34 requirements
- KS-801 and KS-802 fulfill USP-NF L22 and L58 requirements
|
| KF-800D |
- Use this column in combination with a linear column
- Accurate molecular weight distribution of polymers and oligomers are achieved by shifting the elutions of monomers, polymer additives, and solvent-peak in the lower molecular region.
|