PRODUCT

  1. Home
  2. chevron_right
  3. Products
  4. chevron_right
  5. Laboratory Supplies
  6. chevron_right
  7. Electrochemical Instruments
  8. chevron_right
  9. Battery Cyclers
  10. chevron_right
  11. IviCycle
  12. chevron_right
  13. IviCycle C200

IviCycle C200

The IviCycle C200 is designed to be your perfect partner for high channel-count battery applications. The IviCycle offers a low cost-per-channel, high volume testing solution and extensive data storage capability.

The IviCycle is a multi-channel test system with optional impedance capability. The channels are divided over 4 modules. It is possible to mix and match different IviCycle modules to create the desired number of channels with varying compliance.

The C200 modules each have 8 channels of ±200mA/±10V compliance. The modules are available either as a DC version (no EIS), or as an EIS version with impedance capability on each of the channels. This means that simultaneous/parallel impedance measurements are possible on all channels. The IviCycle has an integrated DataSecure module that stores all data for each channel completely independently from the computer. This ensures that if there is a communication loss or a computer crash/update, the measurement will continue and data will not be lost. This provides peace-of-mind for long duration, high throughput testing. The IviCycle unit is built into a 19inch rack mountable housing for easy incorporation into existing storage racks, or as a stand-alone bench-top multi-channel system.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Multi-channel battery test system
  • Each channel: ±200mA/±10V
  • Optional FRA/EIS: 10µHz-20kHz on each channel for simultaneous testing
  • 19″ rack-mountable housing
  • Low cost-per-channel battery test solution

Specifications

System performance
Current compliance ±200mA
Maximum applied voltage ±10V
Electrode connections
4; WE, CE, RE, S with 4mm banana plugs
Potentiostat bandwidth >500kHz
Stability settings High Speed, Standard and High Stability
Signal acquisition Dual channel 18bit ADC, 100,000 samples/s
Channel combination No
Potentiostat
Applied potential range ±10V, 0.08mV res.
Applied potential accuracy 0.2% or 1mV
Current ranges ±10nA to ±100mA
Measured current resolution 0.003% of current range, minimum 0.3pA
Measured current accuracy 20pA + 0.025% of FSR
Galvanostat
Applied current resolution
0.008% of applied current range
Applied current accuracy 0.2%
Galvanostatic current ranges ±10µA to ±100mA
Potential ranges ±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
Measured potential resolution 0.0008% of potential range, minimum 7nV
Measured potential accuracy 0.2% or 1mV
Impedance Analyser
Frequency range 10µHz to 20kHz
Amplitude 0.15mV to 1.0V, or 0.03% to 100% of current range
Electrometer
Input impedance >1000Gohm //<20pF
Input bias current <20pA
Bandwidth
>5MHz
Peripheral connections
Analog in/out ±10V input only, 16bit resolution, bandwidth 40kHz
Environment
Power requirements 100-240V, 50-60Hz, 120VA
Interfacing USB/LAN (Ethernet)
Size (w x d x h) 44 x 26 x 22cm
Weight 12.5kg
PC requirements Windows 8/10/11, with free USB port
Integrated DataSecure Data acquisition time: 2ms minimum, Stored no. of data points: 20M each channel

Measured current accuracy

Manufacturers

show DATA — DO NOT CHANGE ID–

Industries

show DATA — DO NOT CHANGE ID–

No results found.