.

PRODUCT

  1. Home
  2. chevron_right
  3. Products
  4. chevron_right
  5. Laboratory Supplies
  6. chevron_right
  7. Electrochemical Instruments
  8. chevron_right
  9. Battery Cyclers
  10. chevron_right
  11. OctoStat
  12. chevron_right
  13. OctoStat5000

OctoStat5000

The instrument is designed for applications where multiple cells are operated in parallel for long periods of time, such as battery/fuel cell-testing, electrode development, biotechnology and corrosion.

The OctoStat offers a complete package. The hardware includes a built-in dedicated Frequency Response Analyser for each channel, low current measurement possibility down to 100pA full-scale with fA resolution, and an analog measurement channel for secondary signals such as temperature. All measurement and dataprocessing software is included.

The maximum current or potential of the instrument can be defined by the operator. Thus valuable samples may be protected, and unsafe situations prevented.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Each channel: ±5A/±10V FRA/EIS: 10µHz-100kHz (1MHz optional)
  • 8-channel Potentiostat/Galvanostat/ZRA
  • 19″ rack-mountable housing
  • Affordable high-spec electrochemical test system

Specifications

System performance
Current compliance ±5A
Maximum compliance voltage ±10V
Maximum applied voltage ±10V
Electrode connections
4; WE, CE, RE, S with 4mm banana plugs
Potentiostat bandwidth >500kHz
Stability settings High Speed, Standard and High Stability
Programmable response filter 1MHz, 100kHz, 10kHz, 1kHz, 10Hz
Signal acquisition Dual channel 18bit ADC, 100,000 samples/s
Channel combination No
Potentiostat
Applied potential range ±10V, 0.08mV res.
Applied potential accuracy 0.2% or 2mV
Current ranges
±100pA to ±10A
Measured current resolution 0.003% of current range, minimum 0.3pA
Measured current accuracy 20pA + 0.025% of FSR
Galvanostat
Applied current resolution
0.008% of applied current range
Applied current accuracy 0.2%
Galvanostatic current ranges ±10nA to ±10A
Potential ranges ±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
Measured potential resolution 0.0008% of potential range, minimum 7nV
Measured potential accuracy 0.2% or 2mV
Impedance Analyser
Frequency range 10µHz to 100kHz (1MHz optional)
Amplitude 0.15mV to 2.0V, or 0.03% to 100% of current range
DC offset 16bit DC offset subtraction and 2 DC-decoupling filters
Electrometer
Input impedance >1000Gohm //<20pF
Input bias current <20pA
Bandwidth
>5MHz
Special functions
Ohmic drop compensation 2V/current range
Peripheral connections
Analog in/out 2 per channel (±10V, 16bit resolution, bandwidth 40kHz)
Data Acquisition
Data acquisition time 10µs min.
Stored no. of datapoints 20M each channel
Environment
Interfacing USB/LAN (Ethernet)
PC requirements
Windows 8/10/11, with free USB port
Module height 2U
Integrated DataSecure
Data acquisition time: 2ms minimum, Stored no. of data points: 20M each channel

Manufacturers

show DATA — DO NOT CHANGE ID–

Industries

show DATA — DO NOT CHANGE ID–

No results found.

Menu