The Vertex.20A is a versatile entry-level potentiostat which has ±20A/±2V compliance and optional integrated impedance analyser up to 1MHz.

The Vertex.20A has a peripheral port which it uses for connection to the RE and S cable. External interfacing and compatibility has some limitations when compared to the other Vertex instruments (see our compatibility table for reference).

The Vertex can optionally be expanded with a True Linear Scan module, and/or FRA/EIS capability.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Compliance: ±20A/±2V
  • Optional FRA/EIS: 10µHz to 1MHz
  • Optional True Linear Scan generator

Specifications

System performance
Number of channels in instrument
1
Current compliance ±20A
Maximum compliance voltage ±2V
Maximum applied voltage ±2V
Electrode connections 4; WE, CE, RE, S (and GND) with 4mm banana plugs
Potentiostat bandwidth >500kHz
Stability settings High Speed, Standard and High Stability
Programmable response filter 1MHz, 100kHz, 10kHz, 1kHz, 10Hz
Signal acquisition Dual channel 18bit ADC, 300,000 samples/s
Potentiostat
Applied potential range ±2V, 0.08mV res.
Applied potential accuracy 0.2%, or 2mV
Current ranges ±100pA to ±10A
Measured current resolution 0.003% of current range, minimum 3fA
Measured current accuracy 20pA + 0.025% of FSR
Galvanostat
Applied current resolution 0.008% of applied current range
Applied current accuracy 0.2%
Galvanostatic current ranges ±10nA to ±10A
Potential ranges ±1mV, ±4mV, ±10mV, ±40mV, ±100mV, ±400mV, ±1V, ±4V, ±10V
Measured potential resolution 0.0008% of potential range, minimum 7nV
Measured potential accuracy 0.2% or 2mV
Impedance Analyser
Frequency range 10µHz to 1MHz
Amplitude 0.15mV to 2.0V, or 0.03% to 100% of current range
DC offset 16bit DC offset subtraction and 2 DC-decoupling filters
Electrometer
Input impedance >1000Gohm //<10pF
Input bias current <20pA
Bandwidth >5MHz
Special functions
Ohmic drop compensation 2V/current range
Floating operation User selectable
Environment
Power requirements 100-240V, 50-60Hz, 2A
Interfacing USB
Size (w x d x h) 15 x 36 x 4.5cm
Weight 2.5kg
PC requirements Windows 8/10/11, with free USB port