SetaVap4 Automatic Vapour Pressure Analyser – 80600-0
The SetaVap4 is a fully automated vapour pressure analyser which provides fast, reliable and precise analysis of a wide range of volatile liquids, including gasoline, solvents and light crude oil.
The measurement system uses a piston based design in compliance with triple and single expansion test methods and regulations, reporting DVPE, RVP, EPA and CARB calculations. For precise results, the minimum dead volume design reduces sample carryover and a fully automated test sequence removes possible operator bias.
A colour touch screen and clear user interface guides the operator through the menu system and simple operator sequence. Results are stored internally and can be viewed on the screen or saved directly to a USB memory stick for further data management and analysis.
SetaVap4 Automatic Vapour Pressure Analyser – 80600-0
Features
- Rapid, automatic testing
- Simple test procedure
- Compact, rugged design for portable or laboratory use
- Real time display of test progress and storage for 500,000 results
- LIMS connectivity and RS232C serial port, results can be saved to USB or transferred via QR code
- Statistical Quality Control (SQC) software to analyse results to conform to ASTM D6299
- Test multiple temperatures and multiple V/L ratios (ASTM D6377)
specifications
TEMPERATURE RANGE | 0 to 120 °C (no external cooling required). Test the sample for multiple temperatures (ASTM D6377) |
---|---|
PRESSURE RANGE | 0-1000 kPa |
PRESSURE RESOLUTION | User specified – 0 to 2 decimal places |
UNITS OF PRESSURE | kPa, psi |
TEMPERATURE ACCURACY | better than 0.05 °C |
VAPOUR TO LIQUID RATIO | 0.02:1 to 20:1. Test the sample for multiple V/L ratios (ASTM D6377) |
SAMPLE VOLUME | 1 ml, plus rinsing |
MEASUREMENT TIME | <10 minutes for D5191 |
LUBRICATION | Automatic |
VOLTAGE | 100/240 Vac, 50/60 Hz, Auto-sensing universal power supply |
POWER | 300 W |
SIZE (HXWXD) | 310 x 200 x 240 mm |
WEIGHT | 8 kg |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 80600-0
Inlet Nozzle O-Ring (pack of 5) – 80600-004
For use with SetaVap4 80600-0, pack of 5.
Sample Inlet Filter (pack of 5) – 80600-003
For use with SetaVap4 80600-0, pack of 5.
Lubrication Oil (60 ml) – 80600-008
Tubing Kit – 80600-001
For SetaVap4 80600-0. Includes sample inlet and waste tubes.
Vapour Pressure – Certified Reference Material, Pentane 200 ml – 80610-0
Suitable for verification of Setavap and other mini method instruments, used to determine the vapour pressure of volatile liquid petroleum products, ethanol blends, hydrocarbons and hydrocarbon-oxygenate mixtures.
Temperature Calibration Kit – 80601-0
For temperature calibration of SetaVap4 80600-0. Includes digital thermometer and custom probe.
Vacuum Pump – 22422-6
Maximum vacuum 2 x 10^-2 mbar. For use with the Setavap 2 Vapour Pressure Tester (81000-2).
Portable Digital Barometer – 99910-2
Highly accurate, handheld barometer suitable for the most demanding field or laboratory conditions.The barometer allows you to measure absolute pressure, barometric pressure (corrected to sea level) or altitude based upon sea level or corrected for a map or trig marker.You can display pressure in one of seven different engineering units. Altitude can be displayed in either meters or feet. The barometer has a leak test mode to determine the rate of leakage in a pneumatic system, with data logging which is either automatic (taking readings every 5 seconds for 20 minutes) or manual for up to 240 readings.
MTVM – Motor Gasoline 500 ml – 99854-0
A unique secondary reference material that provides traceable validation of different test parameters from one sample. Rapid global delivery and compliance with ISO 17025 & ISO 9001 requirements, mean that Seta’s verification materials offer readily available support for laboratory accreditation and compliance programmes.Incorrect determination of a result can have far reaching financial and safety implications. The growing use of automated instrumentation increases the possibility that incorrect results may go undetected and in addition the early indication of bias is a useful warning to minimise production ‘giveaway’.Certification: Supplied with a Certificate which gives the certified value for each test method covered by the material.