Sensit Smart
The Sensit Smart is the world smallest ready-to-go potentiostat available on the market. The Sensit Smart can be directly inserted in a smartphone or tablet and controlled via the Android app PStouch. You can use the USB-C Female to USB-A cable to connect the Sensit Smart to a classic USB port on your PC and control the Sensit Smart via our PC software PSTrace.
The Sensit Smart supports most common electrochemical techniques, including Cyclic Voltammetry, Square Wave Voltammetry and Impedance Spectroscopy (FRA/EIS).
Features
- Dummy Cell (SPE version)
- SPE to screw-terminal adapter
- USB-C Female to USB-A cable
- USB-C Female to Micro USB adapter
- USB-C Extension cable
- USB-C port protector
- PSTrace software for Windows (activation code for my.palmsens.com)
- PStouch app for Android (find it in the Google Play Store)
- Compatible with most common Screen Printed Electrodes / Sensors
Specifications
Compatibility |
|||
---|---|---|---|
Sensor pitch | 2.54 mm | ||
Electrode connections | RE, WE, CE | ||
Allowed sensor thickness | Between 0.1 mm and 0.8 mm | ||
Maximum sensor width | 11 mm | ||
General |
Low Speed mode |
High Speed mode |
Max Range mode |
Full dc-potential range | -1.2 to +2 V | -1.7 to +2 V | -1.7 to +2 V |
Dynamic dc-potential range1 | 2.2 V | 1.2 V | 2.6 V |
Compliance voltage | -2.0 to +2.3 V 2 | ||
Maximum current | ± 3 mA | ||
Max. acquisition rate (datapoints/s) |
100 | 1000 | 100 |
Supports FRA/EIS | NO | YES | NO |
Potentiostat (controlled potential mode) |
|||
Channels | 1 (1x WE, 1x RE and 1x CE) | ||
Applied dc-potential resolution | 537 µV | 395 µV | 932 µV |
Applied potential accuracy | < 0.2% | < 0.5% | < 0.5% |
Current ranges | 100 nA, 2 uA, 4 uA, 8 uA, 16 uA, 32 uA, 63 uA, 125 uA, 250 uA, 500 uA, 1 mA, 5 mA |
100 nA, 1 uA, 6 uA, 13 uA, 25 uA, 50 uA, 100 uA, 200 uA, 1 mA, 5 mA | 100 nA, 1 uA, 6 uA, 13 uA, 25 uA, 50 uA, 100 uA, 200 uA, 1 mA, 5 mA |
Current accuracy | < 0.5 % of the selected current range < 2% for 100 nA current range |
< 1% of the selected current range | < 1% of the selected current range |
Measured current resolution | 0.006% of selected current range (5.5 pA on 100 nA range) | ||
Measured potential resolution | 56 uV | ||
FRA / EIS (impedance measurements) |
|||
Frequency range | 0.016 Hz to 200 kHz | ||
Ac-amplitude range | 1 mV to 0.25 V rms, or 0.708 V p-p | ||
Electrometer | |||
Electrometer amplifier input | > 1 TΩ // 10 pF | ||
Bandwidth | 250 kHz | ||
Other |
|||
Power and communication | USB-C | ||
Storage | 4000 datapoints on-board | ||
Size | 43 x 25 x 11 mm (excl. USB connector) | ||
Weight | 10 g | ||
Battery | No | ||
Auxiliary port | No | ||
Sensor connector | SPE (pitch: 2.54 mm) | ||
Operation temperature range | 0 °C to +40 °C |
(1) The dynamic range is the range that can be covered during a single scan within the full potential range. For example; a linear scan can start at -1.5 V and end at 1.1 V or vice versa, covering 2.6 V dynamic range.
(2) The compliance voltage is the maximum potential between Working and Counter electrode and depends on the selected mode.
Techniques
Voltammetric techniques
- Linear Sweep Voltammetry (LSV)
- Cyclic Voltammetry (CV)
Pulsed techniques
- Differential Pulse Voltammetry (DPV)
- Square Wave Voltammetry (SWV)
- Normal Pulse Voltammetry (NPV)
Amperometric techniques
- Chronoamperometry (CA)
- Chronocoulometry (CC)
- MultiStep Amperometry (MA)
- Pulsed Amperometric Detection (PAD)
Galvanostatic techniques
- Open Circuit Potentiometry (OCP)
Electrochemical Impedance spectroscopy (EIS)
- Potential scan
- Fixed potential
- Time scan
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–