PRODUCT

High Pressure In-line Conductivity Sensor ATEX Ex Certified (D2 JF-1AHP) – 99505-0

An inline system that provides real time measurement of conductivity in pipelines using high accuracy AC measurement technology.

The system can be connected to a refinery/terminal management system to provide an automatic and continuous record of product conductivity levels, eliminating the requirement for manual sampling and record keeping. When installed with an automatic dosing system the in-line sensor allows automated additive dosing to maintain the conductivity within specified limits.

The conductivity sensor comprises two stainless steel coaxial electrode sensors and is suitable for long-term immersion in fuels.

NOTE: Installation documents and schematics are available on request.

Do NOT CHANGE OR REMOVE THIS ELEMENT

High Pressure In-line Conductivity Sensor ATEX Ex Certified (D2 JF-1AHP) – 99505-0

Features

  • In-line Conductivity and temperature measurement conforming to ASTM D2624
  • Conductivity range 0 to 2000 pS/m
  • Accuracy +/-2% of reading
  • Temperature range -40° to 85 °C +/-0.5°C
  • Standard 100 bar max line pressure
  • 4-20 mA output
  • Stainless Steel construction
  • ATEX Certified

Specifications

Range 0 to 2000 pS/m
Accuracy +/-2 pS/m (+/-2% of reading)
Pressure 100 bar max pressure
Temperature Range -40° to 85 °C, Accuracy +/-0.5 °C
Resolution 0.1 pS/m
Sensor Type 316 SS Coaxial Electrode
Calibration Internal Source Zero and Scale
Certification Ex II 2 G Ex db ia IIB+H2 T4 Gb
CCCN Code Tariff 90318080

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

JF-1A In-Line Conductivity Sensor Brochure

Industries

show DATA — DO NOT CHANGE ID–

Spares and accessories for High Pressure In-line Conductivity Sensor ATEX Ex Certified (D2 JF-1AHP) – 99505-0

JF-1A Local Readout Display NPT Entry(ATEX) – 99520-0

A loop powered field indicator in a single compartment housing for use with the JF-1A Inline Conductivity Sensor (99500-0).

Explosion proof enclosure 5-digit LC display, Aluminium die cast housing, NPT cable entry and ATEX II2(1)G EX ib[ia] IIC T6/T5/T4.

Supplied with works calibration certificate.

JF-1A Local Readout Display M20 Entry(ATEX) – 99508-0

A loop powered field indicator in a single compartment housing for use with the JF-1A Inline Conductivity Sensor (99500-0).

Explosion proof enclosure 5-digit LC display, Aluminium die cast housing, M20 cable entry and ATEX II2(1)G EX ib[ia] IIC T6/T5/T4.

Supplied with works calibration certificate.

JF-1A USB Serial Test Cable – 99509-0

JF-1A Local Readout Display(FM) – 99507-0

A loop powered field indicator in a single compartment housing for use with the JF-1A Inline Conductivity Sensor (99500-0).

Explosion Proof Enclosure 5-digit LC display, Aluminium die cast housing, NPT1/2 Cable entry and FM approval.

Supplied with works calibration certificate.

Sun Shield – 99524-0

Sun shield for use with the Inline Conductivity Sensors (99500-0).