FIJI DRG – FAME in Distillate & Residual Fuels – SA5100-0
The patented FIJI DRG offers a rapid and easy check on parts per million (ppm or mg/kg) levels of FAME in distillates, residuals and gasoline.
FIJI uniquely utilises state of the art FTIR (Fourier Transform Infra-Red Spectroscopy) technology and a patented sample preparation system which allows FAME detection accuracy down to the 20 mg/kg level.
FIJI DRG can be used as a field or lab based screening tool to give a quick indication of possible FAME contamination that may then require further investigation. The instrument can be used to prevent expensive testing and avoid costly delays of fuel release.
A Multi-Product version of FIJI is available to measure Distillate & Residual Fuels as well as Jet.
Existing users of FIJI DRG can upgrade to enable measurement of FAME in Jet Fuels in accordance with ASTM D7797 & IP 583 using SA5050-0.
FIJI DRG – FAME in Distillate & Residual Fuels – SA5100-0
Features
- FAME in Distillate & Residual Fuels
- Measures the presence of all FAME types C8 to C22
- Approved for co-processed fuels
- Analysis time 20 minutes
- 50ml sample volume
- Measuring range 20 mg/kg to 20%
- Laboratory and field instrument
- Suitable for untrained operators
- Fully automatic
- Patent Approved
specifications
MEASUREMENT RANGE | 20 mg/kg to 20% |
---|---|
TEST DURATION | 20 minutes |
SAMPLE SIZE | 50ml |
OPERATING TEMPERATURE RANGE | 5 to 35°C maximum (80% RH) |
CONNECTIVITY | USB ‘A’ (2 ports), LIMS |
POWER | 50W maximum |
VOLTAGE | 100/250V, 50/60Hz |
SIZE (HXWXD) | 55 x 38 x 42 cm |
WEIGHT | 27 kg |
CCCN CODE | Tariff 90273000 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for SA5100-0
FIJI IP 583, ASTM D7797 and ASTM D7963 Starter Kit – SA5201-0
FIJI Beaker 50 ml (pack of 100) – SA5004-100
FIJI Low Lint Wipes (pack of 280) – SA5003-0
FIJI ASTM D7963 Annual Service Kit – SA5115-0
FIJI DRG Range Extender Diluent 5 L – SA5029-0
FIJI ASTM D7963 Cartridges (pack of 100) – SA5105-100
FIJI IP 583 and ASTM D7797 Cartridge (pack of 100) – SA5005-100
FIJI Verification Material 100 ppm, 100 ml – SA5021-0
FIJI Verification Material 30 ppm, 100 ml – SA5020-0
FIJI Verification Material for use with the FIJI JF – FAME in Jet Instrument (SA5000-2), FIJI DRG – FAME in Distillate & Residual Fuels (SA5100-0) and FIJI MF – FAME in MultiFuels (SA5200-0).
FIJI Verification Material 400 ppm, 100 ml – SA5122-0
FIJI Verification Material for use with the FIJI JF – FAME in Jet Instrument (SA5000-2), FIJI DRG – FAME in Distillate & Residual Fuels (SA5100-0) and FIJI MF – FAME in MultiFuels (SA5200-0).
FIJI ASTM D7963 Calibration Material Set – SA5125-0
Pack of 9 x FIJI Calibration Material for use with the FIJI DRG – FAME in Distillate & Residual Fuels (SA5100-0) and FIJI MF – FAME in MultiFuels (SA5200-0).