Setaflash Series 3 Flash Point Tester – 30000-3

The Setaflash Series 3 closed cup flash point tester provides fast and reliable flash point results and requires minimum expertise.

With the Series 3, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Ambient to 300 °C
  • Simple test procedure
  • Compact, rugged design
  • Automated flash detection
  • Ramp mode
  • Automatic barometric pressure correction
  • USB port and result storage

specifications

TEMPERATURE RANGE Ambient to 300 °C
TEMPERATURE SELECTION °C or °F
HEATING/COOLING METHOD Cartridge
TEMPERATURE RAMP MODE/th>

Up to 6 °C/min

DATA STORAGE 1 GB
VOLTAGE 100 to 240 Vac, 50/60 Hz
SIZE/WEIGHT 195 x 295 x 140mm / 3 kg
CCCN CODE Tariff 90268020

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

Setaflash Series 3 Flash Point Tester – 30000-3

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for 30000-3

Sample Well O-Ring, Silicone (Pack of 5) – 13770-004

Suitable for most samples except JET A1/Aviation Fuels and Kerosines. For high temperature applications with Setaflash Series 3 Flash Point Testers and gas ignition Series 8 Flash Point Tester models.

Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311

4 ml sample volume syringe, which must be used for flash points above 100 °C.

Silicone Rubber Tube 4 metres – 13730-005

Replacement gas tubing for use with Flash Point Testers.

Sample Well O-ring, Viton (Pack of 5) – 13740-004

Viton, 1/8th inch. Suitable for JET A1/Aviation fuels and kerosines. For use with Setaflash Series 3 Flash Point Testers or gas ignition Series 8 models, for temperatures up to 200 °C.

Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009

2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.

Flash Detector Assembly – 13740-425

For use with the Setaflash Series 3 Flash Point Tester range.