PRODUCT

Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2

The Setaflash Series 8 closed cup flash point tester provides fast and reliable flash point results with a wide temperature range from ambient to 300 °C with no external cooling required.

With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores test results which can be saved and transferred via a USB port to a laboratory information management system (LIMS).

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2

Features

  • Simple test procedure
  • Compact, rugged design
  • Electric ignition
  • Automated flash detection
  • Ramp mode for unknown samples
  • Statistical quality control system
  • Automatic barometric pressure correction
  • Fire detection (alarm and relay)
  • USB port and result storage

specifications

TEMPERATURE RANGE Ambient to 300 °C
TEMPERATURE SELECTION °C or °F
IGNITOR Electric
HEATING/COOLING METHOD Ceramic hotplate and fan
TEMPERATURE RAMP MODE Automatic or custom settings (ramp rate up to 10 °C/min)
SAMPLE CUP MATERIAL Aluminium
PRESSURE CORRECTION Automatic
DATA STORAGE 12 GB
VOLTAGE 110 to 240 Vac, 50/60 Hz auto-sensing power supply
SIZE (HXWXD) 300 x 340 x 380 mm
WEIGHT 8 kg
CCCN CODE Tariff 90268020

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for 82000-2

Printer Paper (Pack of 20) – 80602-001

Printer paper, pack of 20, for use with 80602-0 Serial Printer.

Flash Detector for Series 8 – 82000-201

Flash detector for use use with the Series 8 ActiveCool Flash Point Tester.

High Temperature Ignitor for Series 8 and Series 3 – 82000-202

High Temperature Ignitor for use use with the Series 8 and Series 3 ActiveCool Flash Point Testers.

Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311

4 ml sample volume syringe, which must be used for flash points above 100 °C.

Sample Well O-Ring Ekraz – 82000-018

Sample well O-ring for use with the Setaflash Series 8 Closed Cup Flash Point Tester (82000-0 and 82000-2) and the Setaflash Series 8 ActiveCool Flash Point Tester (82150-2). For use with sample cups with a 1/6 inch O-ring groove. Can be used with all samples.

Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009

2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.