Seta Auto-Oxidation Stability Bath – 15400-5
This unit measures the induction period for oxygen in gasoline, and allows the weight of gum and residue in aviation fuel to be determined by direct weighing.
Comprising a heated water bath with reflux condenser, a cold water plunge tank for cooling test vessels after each test, and an integral system for charging oxidation vessels prior to test. The Seta Auto-Oxi Control System (15452-2) provides automatic monitoring of up to four pressure test vessels. High quality pressure transducers and system components ensure reliable operation and fully traceable results
Seta Auto-Oxidation Stability Bath – 15400-5
Features
- Operating temperature 100°C
- Water Bath with integral condenser
- 4 x test stations
- Cold plunge bath
- Seta Auto-Oxi Automatic Pressure Monitoring
- Integral vessel charge system
- Constant level device
specifications
CAPACITY | 60 litres |
---|---|
FLUID TYPE | Water |
TEMPERATURE | Bath: 100 °C Thermometer: 0 to 105 °C |
MAX NO OF TEST VESSELS | 4 (Not included with the instrument) |
VESSEL CHARGING | 1380 kPa (200 psi) maximum |
VESSEL COOLING | Cold water plunge tank |
PRESSURE RANGE/ACCURACY | 0-1600 kPa (0-16 bar)/0.1% of span |
MAX TEST DURATION | 120 hrs / 7200 mins |
CALIBRATION | Pressure and Temperature sensing with traceable certificate |
SAFETY & PROTECTION | CE certified / IP 67 rated |
SOFTWARE OPERATING REQUIREMENTS | Windows XP,Vista,7, or 8 (32 and 64 bit) USB or LAN Printer (optional) |
POWER | 3 kW |
VOLTAGE | 220/240 V, 50/60 Hz |
SIZE (HXWXD)/WEIGHT | 930 x 865 x 715 mm / 118 kg |
CCCN CODE | Tariff 90268020 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 15400-5
Vessel Bench Clamp and Holder – 15803-0
Seta Auto-Oxidation Stability Bath (15400-5)
Seta Oxi-Cor Bath (15550-3)
Oxi Solid Block Bath 4 Way (16670-0)
Liner with Cover (Pack of 3) – 15810-0
Borosilicate glass with cover.
For use with;
Seta Auto-Oxidation Stability Bath (15400-5)
Seta Oxi-Cor Bath (15550-3)
Oxi Solid Block Bath 4 Way (16670-0)
Spanner – 15805-0
For use with;
Seta Auto-Oxidation Stability Bath (15400-5)
Seta Oxi-Cor Bath (15550-3)
Oxi Solid Block Bath 4 Way (16670-0)
Oxidation Vessel – 15802-2
Transducer, 0 to 1600 kPa – 15455-3
Used for auto pressure monitoring, one required for each test vessel in use. Provided with a USB output.
For use with the Seta Auto-Oxi Control System (15452-2).
Glass Liner Only (Pack of 3) – 15810-002
For use with Seta oxidation baths (15400-5, 15550-3 and 16670-0).
Cover for Liner (Pack of 10) – 15810-001
For use with the Seta Auto-Oxidation Stability Bath (15400-5).