Pack of 80 x 20 ml syringes for use with the AFIDA (SA6000-0).
AFIDA – Indicated Cetane Number Analyser – SA6000-0
AFIDA is a revolutionary development providing you with a fully automated way of determining Indicated Cetane Number (ICN) of diesel and diesel related fuels. The AFIDA can analyse multiple samples in sequence and selects the samples using the 36-place autosampler. Only a small sample volume of 40 ml is required per test with a short analysis time of approximately 25 minutes.
The analyser uses a Constant Volume Combustion Chamber (CVCC) and incorporates a unique and patented high pressure injection system that generates fine fuel droplets similar to modern common rail injectors in most diesel engines.
An ultra robust temperature controlled piezo electric injector provides rapid switching and highly repeatable fuel metering, offering you improved performance and consistency when compared with solenoid controlled injectors and pintle type nozzles.
AFIDA – Indicated Cetane Number Analyser – SA6000-0
Features
- Excellent correlation to ASTM D613, IP 41 and BS EN ISO 5165, BS 2000-41, ISO 5165
- Wide sample types – middle distillates, blend components, biodiesel, FAME, XTL, HVO, heating oil and Jet A1
- Suitable for use with Cetane improvers
- Calibrated with industry approved PRFs over the range 35 to 85 ICN
- Precise and reproducible software controlled determination of ICN
- Results saved to PC or for download
- Stable calibration – fixed test conditions eliminates routine temperature tuning
- Low running costs, single gas supply for combustion air
- Direct correlation to ASTM D613 (ISO 5165) engine tests
- Multiple integral safety monitoring functions
- Standardisation
Specifications
Chamber Temperature | 580 °C |
---|---|
Chamber Pressure | 17.5 bar |
Injection Pressure | 1000 bar |
Compressed Air | 20.9 ± 0.5 % O2 |
Sample Volume | approx. 40 ml for analysis and cleaning |
Warm Up Time | approx. 45 min |
Analysis Time | approx. 25 min per sample |
Size (DXHXW) | 1300 mm x 800 mm x 600 mm (excluding platform) |
Weight | 160 kg 100 kg (excluding platform) |
CCCN Code | Tariff 90318080 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for Cetane Number Analyser
Pressure Regulator Panel AFIDA – SA6005-0
Pressure regulator panel to connect and regulate the air supply to the AFIDA (SA6000-0). Includes a wall mounted regulator, filter and pressure gauge.
AFIDA Start Up Kit – SA6003-0
Start up kit to perform 100 AFIDA (SA6000-0) tests. Supplied with 1 x PRF calibration set, 1 x ambered vials (pack of 100), 1 x septums (pack of 100), 1 x caps (pack of 100), 1 x syringe filters (pack of 100), 1 x 500 ml cleaning fluid, 1 x 5 litre antifreeze coolant, 1 x pump valve service kit, 1 x verification fluid, 1 x torque wrench tool kit, 1 x 20 ml syringes (pack of 100)
Cleaning Fluid – SA6003-006
500 ml bottle of 1-decanol cleaning fluid for use with the AFIDA (SA6000-0).
AFIDA Syringes (pack of 80) – SA6003-005
AFIDA Syringe Filters (pack of 100) – SA6003-004
Pack of 100 syringe filters for use with the AFIDA (SA6000-0).
AFIDA Caps (pack of 100) – SA6003-003
Pack of 100 caps for use with the AFIDA (SA6000-0).
AFIDA Septums for Sample Vials (pack of 100) – SA6003-002
Pack of 100 septums for use with the ambered sample vials for the AFIDA SA6000-0.
AFIDA Ambered Vials (pack of 100) – SA6003-001
Pack of 100 ambered vials for use with the AFIDA (SA6000-0).
AFIDA PRF Calibration Set – SA6002-0
A set of calibration fluids for use with the AFIDA (SA6000-0). The set includes seven glass vials that cover calibration points of Indicated Cetane Number (ICN) 35, 40, 46, 53, 60, 70 and 85. The vials consist of volumetric blends of primary reference fuels n-hexadecane and 1-methylnapthalene.
Verification Fluid (pack of 4) – SA6009-0
Pack of 4 x 40 ml verification fluid vials for use with the AFIDA (SA6000-0).