PRT probe or use with the Multiflash Pensky-Martens Flash Point Module (34100-2).
Auto-Abel Flash Point Tester – 34200-2
The automatic Abel module conforms precisely to national and international Abel flash point test methods. It comprises the multiflash base unit, a water bath, sample cup and lid, temperature probes, flash detector, and a DIPS pod containing the dipping mechanism with co-axial gas/electric ignitor, and a stirrer.
The Auto-Able incorporates the Multiflash Universal Base Unit (34000-0) and the Cooling Boost Module (34008-0).
Auto-Abel Flash Point Tester – 34200-2
Features
- Full test method compliance
- Equilibrium and non-equilibrium tests
- Automatic set up of test parameters
- Gas or electric ignition
- Automatic heating control and flash detection
- Automatic test results with end of test audible warning
- Centigrade or Fahrenheit temperature displa
- Automatic barometric correction
specifications
TEMPERATURE RANGE | 5 to 83 °C (-20 °C to 83 °C with optional cryostat 34006-3) |
---|---|
HEATING | Cartridge heaters |
POST TEST COOLING | Fan assisted or circulating liquid / external cryostat |
POST TEST COOL-DOWN TIME (80°C TO 50°C) | 45 minutes (fan) 3 minutes (external cryostat) |
IGNITOR | Quick-fit coaxial gas jet / electric hot wire, user selectable (electric hot wire pilot light for gas jet) |
TEMPERATURE PROBES | Class A platinum resistance thermometers |
STIRRER SPEED | 30 rpm |
GAS SUPPLY (GAS JET IGNITOR) | Laboratory gas, 3 kPa (0.44 psi) maximum pressure |
COOLING SUPPLY | Water (5 °C and above) Water / ethylene glycol 50/50 (below 5 °C) 125 kPa (18 psi) maximum pressure |
VOLTAGE | 110/120 V or 220/240 V, 50/60 Hz, (switchable) |
POWER | 600 W |
SIZE (HXWXD) | 380 x 470 x 340 mm |
WEIGHT | 13 kg |
CCCN CODE | Tariff 90268020 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 34200-2
PRT Probe (Multiflash Pensky-Martens) – 34100-002
Inner Bath Probe (Multiflash Abel) – 34200-004
Inner bath probe for use with the Multiflash Abel Flash Point Module (34200-0).
Outer Bath Probe (Multiflash Abel) – 34200-003
Outer bath probe for use with the Multiflash Abel Flash Point Module (34200-0).
Flash Detector (Multiflash PMCC, Tag, Abel) – 34100-001
Flash Detector for use with Seta Multiflash Abel Flash Point Module (34200-0) and Seta Multiflash Tag Flash Point Module (34400-0).
Ignitor (Multiflash Abel) – 34200-005
Ignitor for use with the Seta Multiflash Abel Flash Point Module (34200-0).
Dry Well Probe Calibrator – 60005-002
A portable instrument designed to provide quick and accurate calibration of thermocouple and RTD temperature probes.
Portable Digital Barometer – 99910-2
MTVM – Kerosine 500 ml – 99850-0
A unique secondary reference material that provides traceable validation of different test parameters from one sample. Rapid global delivery and compliance with ISO 17025 & ISO 9001 requirements, mean that Seta’s verification materials offer readily available support for laboratory accreditation and compliance programmes.