Printer paper, pack of 20, for use with 80602-0 Serial Printer.
Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2
The Setaflash Series 8 closed cup flash point tester provides fast and reliable flash point results with a wide temperature range from ambient to 300 °C with no external cooling required.
With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores test results which can be saved and transferred via a USB port to a laboratory information management system (LIMS).
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Setaflash Series 8 Closed Cup Flash Point Tester – High Temperature – 82000-2
Features
- Simple test procedure
- Compact, rugged design
- Electric ignition
- Automated flash detection
- Ramp mode for unknown samples
- Statistical quality control system
- Automatic barometric pressure correction
- Fire detection (alarm and relay)
- USB port and result storage
specifications
TEMPERATURE RANGE | Ambient to 300 °C |
---|---|
TEMPERATURE SELECTION | °C or °F |
IGNITOR | Electric |
HEATING/COOLING METHOD | Ceramic hotplate and fan |
TEMPERATURE RAMP MODE | Automatic or custom settings (ramp rate up to 10 °C/min) |
SAMPLE CUP MATERIAL | Aluminium |
PRESSURE CORRECTION | Automatic |
DATA STORAGE | 12 GB |
VOLTAGE | 110 to 240 Vac, 50/60 Hz auto-sensing power supply |
SIZE (HXWXD) | 300 x 340 x 380 mm |
WEIGHT | 8 kg |
CCCN CODE | Tariff 90268020 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 82000-2
Printer Paper (Pack of 20) – 80602-001
Flash Detector for Series 8 – 82000-201
Flash detector for use use with the Series 8 ActiveCool Flash Point Tester.
Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311
4 ml sample volume syringe, which must be used for flash points above 100 °C.
Sample Well O-Ring Ekraz – 82000-018
Sample well O-ring for use with the Setaflash Series 8 Closed Cup Flash Point Tester (82000-0 and 82000-2) and the Setaflash Series 8 ActiveCool Flash Point Tester (82150-2). For use with sample cups with a 1/6 inch O-ring groove. Can be used with all samples.
Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009
2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.
Small Scale Certified Flash Point Material (50 ml) – 99878-3
Small scale flash point material for use with various Seta Flash Point Testers. The material has a nominal certified flash point value of 75 °C (uncertainty 1.2 °C).
Portable Digital Barometer – 99910-2
Highly accurate, handheld barometer suitable for the most demanding field or laboratory conditions.
Thermometer Digital: -199 to 199 °C UKAS Calibrated – 82012-0
High accuracy PT100 thermometer, for checking the calibration and accuracy of Vapour Pressure Testers (81000-2) as well as other temperature sources.
Small Scale Certified Flash Point Material (50 ml) – 99879-0
Small scale flash point material for use with various Seta Flash Point Testers. The material has a nominal certified flash point value of 192 °C (uncertainty +/-2.6 °C).