58 mm width. For use with Data Printer (81002-3).
Seta Multi Filtration Tester (MFT) – 91600-3
The Multi Filtration Tester (MFT) fully conforms to the latest ‘cold soak’ filterability test requirements for FAME and bio diesel. It is a unique and versatile instrument designed to test the Filter Blocking Tendency (FBT) of diesel, biodiesel (B100 & B5/7/20/30), gas oil, gas turbine fuel and kerosene. Test parameters for IP 387 and ASTM D2068 are pre-programmed.
FBT analysis is achieved by measuring the pressure differential across a disposable filter. Fuels which have a high FBT could potentially block filters in the distribution network or during use in a vehicle or power plant.
MFT is also used to determine the FBT for BX fuels containing bio components, such as FAME (biofuel), which have been ‘cold soaked’ at a temperature just above zero Celsius. During the 16 hour cold soak particles of saturated monoglycerides (SMG’s) and sterol glucosides can be formed which do not dissolve when the temperature is raised back to ambient.
Seta Multi Filtration Tester (MFT) – 91600-3
Features
- Portable test for filterability/blocking tendency of Fuel Oils
- Testing of Bio components including FAME material and cold soak testing
- Easy to use, fully automated operation
- Large LCD display
- Results in less than 15 minutes
- Automatic calculation of FBT and F-QF
- Simple calibration/verification of flow, pressure & temperature
- Interface for PC/Printer
specifications
FILTER BLOCKING TENDENCY (FBT) RANGE | 1.0 to 30 (low number is best) |
---|---|
FILTERABILITY QUALITY FACTOR (FQF) RANGE | 100 to 1 (high number is best) |
MAXIMUM PRESSURE | 200 kPa |
POWER SUPPLY | 110/120 V, 50/60 Hz 220/240 V, 50/60 Hz (switchable) |
POWER | 500 W |
SIZE (HXWXD) | 27 x 43 x 26 cm |
WEIGHT | 10 kg |
CCCN CODE | Tariff 90268080 |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 91600-3
Start-up Kit, IP387 and D2068 Procedure A – 91615-0
Supplied with;
1 x filter holder
100 x 1.6 µm filter papers
1 x tweezers
2 x anti-splash tubing
Start-Up Kit, IP387 and D2068 Procedure B, 98 filters – 91616-0
Supplied with;
98 x 1.6 µm encapsulated glass fibre filters
6 x female to female Luer Lock adaptors
Anti-splash tubing
Fuel and Receiver Beaker – 91600-002
Printer Paper (Pack of 20) – 81002-301
Digital Stopwatch – 22750-3
Digital stopwatch with LCD display in water resistant case.
Pressure Calibrator – 91662-0
The digital pressure gauge is designed for hydraulics, pneumatics and mechanical engineering applications. It is quick and easy to install.
Measuring Cylinder – 91660-0
500 ml measuring cylinder for verification/calibration.
Filter Blocking Tendency (FBT) Verification Fluid – 91668-0
The Seta Filter Blocking Tendency (FBT) Verification Fluid is used for checking calibration of the Seta Multi-Filtration Tester (91600-3), including verification of filters, according to IP 387 Procedure B and as referenced in IP PM-EA and CEN N403.
Thermometer Digital: Filtration Tests -199 to 199 ºC – 99922-2
Designed specifically for verification of temperatures associated with ASTM D7501 and Cold Soak Filtration tests.