EmStat4R
The EmStat4R delivers desktop performance in a rugged enclosure. The EmStat4R is a portable Battery or USB-powered Potentiostat, Galvanostat, and optional a Frequency Response Analyzer (FRA) for Electrochemical Impedance Spectroscopy (EIS). The EmStat4R is great for applications that require low currents, from 30 mA down to picoamps, such as sensor applications. The EmStat4R is controlled with PSTrace for Windows, the Android app PStouch, or you can write your own MethodSCRIPT and control it from any platform or operating system.
Features
- Portable: battery, Bluetooth and rugged housing
- Available with connection module for sensor cable or SPE
- Potential range ±3 V
- Max. current ±30 mA
- Optional impedance analyzer: 10 μHz up to 200 kHz
Specifications
General |
|
---|---|
dc-potential range | ±3 V |
compliance voltage | ±5 V |
maximum current | ±30 mA |
max. data acquisition rate | 1M samples /s |
Potentiostat |
|
applied dc-potential resolution | 100 µV |
applied potential accuracy | ≤ 0.2% ±1 mV offset |
current ranges | 1 nA to 10 mA 8 ranges |
measured current resolution | 0.009% of CR (92 fA on 1 nA range) |
measured current accuracy | < 0.2% of current
±20 pA ±0.2% of range |
bandwidth settings | 320 Hz, 3.2 kHz, 30 kHz or 570 kHz |
Galvanostat |
|
current ranges | 10 nA, 1 uA, 100 uA, 10 mA
4 ranges |
applied dc-current | ±3 * CR (current range) |
applied dc-current resolution | 0.01% of CR |
applied dc-current accuracy | <0.4% of current
±20 pA ±0.2% of range |
potential ranges | 50 mV, 100 mV, 200 mV, 500 mV, 1 V |
measured dc-potential resolution | 96 µV at ±3 V (1 V range) 48 µV at ±1.5 V (500 mV) 19.2 µV at ±0.6 V (200 mV) 9.6 µV at ±0.3 V (100 mV) 4.8 µV at ±0.150 V (50 mV) |
measured dc-potential accuracy | ≤ 0.2% ±1 mV offset |
bandwidth settings | 320 Hz, 3.2 kHz, 30 kHz or 570 kHz |
FRA / EIS |
|
frequency range | 10 µHz to 200 kHz |
ac-amplitude range | 1 mV to 900 mV rms, or 2.5 V p-p |
GEIS |
|
frequency range | 10 μHz to 100 kHz (or 10 μHz to 100 kHz) |
ac-amplitude range | 0.001 x CR to 0.4 x CR (<10 mA) 0.001 x CR to 0.2 x CR (10 mA) (CR = current range) |
Electrometer |
|
electrometer amplifier input | > 1 TΩ // 10 pF |
bandwidth | 1 MHz |
Other |
|
electrode connections | Two versions:
|
housing | aluminum body only: 11.1 x 6.0 x 2.7 cm3 with rubber sleeve: 11.8 x 6.8 x 3.3 cm3 |
weight | ± 310 g |
power + communication | USB-C port or Bluetooth |
Battery life |
|
internal storage space | 500 MB, equivalent to > 15M datapoints |
Techniques
Voltammetric techniques
- Linear Sweep Voltammetry (LSV)
- Cyclic Voltammetry (CV)
- Fast cyclic Voltammery (FCV)
- AC Voltammetry (ACV)
Amperometric techniques
- hronoamperometry (CA)
- Zero Resistance Amperometry (ZRA)
- Chronocoulometry (CC)
- MultiStep Amperometry (MA)
- Fast Amperometry (FAM)
- Pulsed Amperometric Detection (PAD)
- Multiple-Pulse Amperometric Detection (MPAD)
Galvanostatic techniques
- Linear Sweep Potentiometry (LSP)
- Chronopotentiometry (CP)
- MultiStep Potentiometry (MP)
- Open Circuit Potentiometry (OCP)
- Stripping Chronopotentiometry (SCP or PSA)
Pulsed techniques
- Differential Pulse Voltammetry (DPV)
- Square Wave Voltammetry (SWV)
- Normal Pulse Voltammetry (NPV)
Other
- Mixed Mode (MM)
- Potentiostatic/Galvanostatic Impedance spectroscopy (EIS / GEIS)
- Potential scan or current scan
- Fixed potential or fixed current
- Time scan
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–