PRODUCT

  1. Home
  2. chevron_right
  3. Products
  4. chevron_right
  5. Laboratory Supplies
  6. chevron_right
  7. Electrochemical Instruments
  8. chevron_right
  9. Single-channel Poteniostats
  10. chevron_right
  11. EmStat4R

EmStat4R

The EmStat4R delivers desktop performance in a rugged enclosure. The EmStat4R is a portable Battery or USB-powered Potentiostat, Galvanostat, and optional a Frequency Response Analyzer (FRA) for Electrochemical Impedance Spectroscopy (EIS). The EmStat4R is great for applications that require low currents, from 30 mA down to picoamps, such as sensor applications. The EmStat4R is controlled with PSTrace for Windows, the Android app PStouch, or you can write your own MethodSCRIPT and control it from any platform or operating system.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Features

  • Portable: battery, Bluetooth and rugged housing
  • Available with connection module for sensor cable or SPE
  • Potential range ±3 V
  • Max. current ±30 mA
  • Optional impedance analyzer: 10 μHz up to 200 kHz

Specifications

General
dc-potential range ±3 V
compliance voltage ±5 V
maximum current ±30 mA
max. data acquisition rate 1M samples /s
Potentiostat 
applied dc-potential resolution 100 µV
applied potential accuracy ≤ 0.2% ±1 mV offset
current ranges 1 nA to 10 mA
8 ranges
measured current resolution 0.009% of CR (92 fA on 1 nA range)
measured current accuracy < 0.2% of current

±20 pA ±0.2% of range

bandwidth settings 320 Hz, 3.2 kHz, 30 kHz or 570 kHz
Galvanostat 
current ranges 10 nA, 1 uA, 100 uA, 10 mA

4 ranges

applied dc-current ±3 * CR (current range)
applied dc-current resolution 0.01% of CR
applied dc-current accuracy <0.4% of current

±20 pA ±0.2% of range

potential ranges 50 mV, 100 mV, 200 mV, 500 mV, 1 V
measured dc-potential resolution 96 µV at ±3 V (1 V range)
48 µV at ±1.5 V (500 mV)
19.2 µV at ±0.6 V (200 mV)
9.6 µV at ±0.3 V (100 mV)
4.8 µV at ±0.150 V (50 mV)
measured dc-potential accuracy ≤ 0.2% ±1 mV offset
bandwidth settings 320 Hz, 3.2 kHz, 30 kHz or 570 kHz
FRA / EIS 
frequency range 10 µHz to 200 kHz
ac-amplitude range 1 mV to 900 mV rms, or 2.5 V p-p
GEIS 
frequency range 10 μHz to 100 kHz (or 10 μHz to 100 kHz)
ac-amplitude range 0.001 x CR to 0.4 x CR (<10 mA)
0.001 x CR to 0.2 x CR (10 mA)
(CR = current range)
Electrometer
electrometer amplifier input > 1 TΩ // 10 pF
bandwidth 1 MHz
Other
electrode connections Two versions:

  • Sensor cable: WE, RE, CE and ground ending in 2 mm banana plugs
  • SPE connector: RE, WE and CE
housing aluminum body only:
11.1 x 6.0 x 2.7 cm3
with rubber sleeve:
11.8 x 6.8 x 3.3 cm3
weight ± 310 g
power + communication USB-C port or Bluetooth
Battery life
  • >6 hours with cell on at 10 mA current
  • charging up to 80% takes approx. 3.5 hours
  • a full charge takes approx. 5 hours
internal storage space 500 MB, equivalent to > 15M datapoints

Techniques

Voltammetric techniques
  • Linear Sweep Voltammetry (LSV)
  • Cyclic Voltammetry (CV)
  • Fast cyclic Voltammery (FCV)
  • AC Voltammetry (ACV)
Amperometric techniques
  • hronoamperometry (CA)
  • Zero Resistance Amperometry (ZRA)
  • Chronocoulometry (CC)
  • MultiStep Amperometry (MA)
  • Fast Amperometry (FAM)
  • Pulsed Amperometric Detection (PAD)
  • Multiple-Pulse Amperometric Detection (MPAD)
Galvanostatic techniques
  • Linear Sweep Potentiometry (LSP)
  • Chronopotentiometry (CP)
  • MultiStep Potentiometry (MP)
  • Open Circuit Potentiometry (OCP)
  • Stripping Chronopotentiometry (SCP or PSA)
Pulsed techniques
  • Differential Pulse Voltammetry (DPV)
  • Square Wave Voltammetry (SWV)
  • Normal Pulse Voltammetry (NPV)
Other
  • Mixed Mode (MM)
  • Potentiostatic/Galvanostatic Impedance spectroscopy (EIS / GEIS)
    • Potential scan or current scan
    • Fixed potential or fixed current
    • Time scan

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

EmState4R Brochure

Industries

show DATA — DO NOT CHANGE ID–

No results found.