Setaflash Series 8 Flash Point Tester with Gas Ignitor – High Temperature – 82050-2

The Setaflash Series 8 High Temperature, closed cup flash point tester provides fast and reliable flash point results with a wide temperature range of 5 to 300 °C.

With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Do NOT CHANGE OR REMOVE THIS ELEMENT

Setaflash Series 8 Flash Point Tester with Gas Ignitor – High Temperature – 82050-2

Features

  • Simple test procedure
  • Compact, rugged design
  • Gas ignition
  • Automated flash detection
  • Ramp mode for unknown samples
  • Automatic barometric pressure correction
  • Fire detection (alarm and relay)
  • USB port and result storage

specifications

TEMPERATURE RANGE Ambient +5 to 300 °C
SAMPLE SIZE 2 or 4 ml according to method
IGNITOR Gas
TEST DURATION, RAPID EQUILIBRIUM 1 minute below 100 °C, 2 minutes above 100 °C, FAME 1 minute or user defined 1 to 99 minutes
TEST DURATION, RAMP MODE Typically 7 minutes
HEATING/COOLING METHOD Ceramic Pad, Forced Air (post-test cooldown)
SAMPLE CUP MATERIAL Aluminium
VOLTAGE 100 to 240 V, 50/60 Hz Auto-sensing
POWER 320 W
SIZE (HXWXD) 300 x 340 x 380 mm
WEIGHT 8 kg

Manufacturers

show DATA — DO NOT CHANGE ID–

Document

Setaflash Series 8 Flash Point Tester with Gas Ignitor – High Temperature – 82050-2

Industries

show DATA — DO NOT CHANGE ID–

Methods

show DATA — DO NOT CHANGE ID–

Spares and accessories for 82110-2

Printer Paper (Pack of 20) – 80602-001

Printer paper, pack of 20, for use with 80602-0 Serial Printer.

Flash Detector for Series 8 – 82000-201

Flash detector for use use with the Series 8 ActiveCool Flash Point Tester.

Sample Well O-ring, Viton (pack of 5) – 82150-001

Pack of 5 x 1/16th inch Viton O-rings, for use with the Setaflash Series 8 Flash Point Tester (82100-0 & 82150-0).

Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311

4 ml sample volume syringe, which must be used for flash points above 100 °C.

Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009

2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.