Setaflash Series 8 Flash Point Tester with Gas Ignitor – High Temperature – 82050-2
The Setaflash Series 8 High Temperature, closed cup flash point tester provides fast and reliable flash point results with a wide temperature range of 5 to 300 °C.
With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Setaflash Series 8 Flash Point Tester with Gas Ignitor – High Temperature – 82050-2
Features
- Simple test procedure
- Compact, rugged design
- Gas ignition
- Automated flash detection
- Ramp mode for unknown samples
- Automatic barometric pressure correction
- Fire detection (alarm and relay)
- USB port and result storage
specifications
TEMPERATURE RANGE | Ambient +5 to 300 °C |
---|---|
SAMPLE SIZE | 2 or 4 ml according to method |
IGNITOR | Gas |
TEST DURATION, RAPID EQUILIBRIUM | 1 minute below 100 °C, 2 minutes above 100 °C, FAME 1 minute or user defined 1 to 99 minutes |
TEST DURATION, RAMP MODE | Typically 7 minutes |
HEATING/COOLING METHOD | Ceramic Pad, Forced Air (post-test cooldown) |
SAMPLE CUP MATERIAL | Aluminium |
VOLTAGE | 100 to 240 V, 50/60 Hz Auto-sensing |
POWER | 320 W |
SIZE (HXWXD) | 300 x 340 x 380 mm |
WEIGHT | 8 kg |
Manufacturers
show DATA — DO NOT CHANGE ID–
Industries
show DATA — DO NOT CHANGE ID–
Methods
show DATA — DO NOT CHANGE ID–
Spares and accessories for 82110-2
Printer Paper (Pack of 20) – 80602-001
Flash Detector for Series 8 – 82000-201
Flash detector for use use with the Series 8 ActiveCool Flash Point Tester.
Syringe 4 ml (Small Scale Flash Point Instruments) – 13770-311
4 ml sample volume syringe, which must be used for flash points above 100 °C.
Syringe 2 ml (Small Scale Flash Point Instruments) – 13740-009
2 ml sample volume must be used for flash points under 100 °C and 2 ml sample volume is required for all FAME products at all temperatures.
Small Scale Certified Flash Point Material (50 ml) – 99878-3
Small scale flash point material for use with various Seta Flash Point Testers. The material has a nominal certified flash point value of 75 °C (uncertainty 1.2 °C).
Portable Digital Barometer – 99910-2
Highly accurate, handheld barometer suitable for the most demanding field or laboratory conditions.
Thermometer Digital: -199 to 199 °C UKAS Calibrated – 82012-0
High accuracy PT100 thermometer, for checking the calibration and accuracy of Vapour Pressure Testers (81000-2) as well as other temperature sources.